12 ULTRACONSOLE INSTALLATION AND OPERATIONS MANUAL
The “Starting computer” number will depend on which Unit is being configured. The “Starting computer” number for
the first Unit is always one (default). Using Units that have 16 CPU ports, the “Starting computer” number for the
second Unit is the total number of CPU ports on the first Unit + one or 17, the third Unit would have a “Starting
computer” number of 33 (Total CPU ports on unit #1 and unit #2 + 1, and so on.
Maximum computers
The “Maximum computers” value is calculated by counting the total number of CPU ports on all units. If your system
consists of 10 UltraConsole Units, each with 16 CPU ports, the “Maximum computers” number would be 160. The
“Maximum computers” value must be entered from a KVM station and when saved, this value is propagated to all
connected Units.
Connecting the expansion units
The installation steps below are for all UltraConsole models.
Steps:
(NOTE: Expansion cables should not be connected at this point)
1. Verify that power is “OFF” on all UltraConsole switches.
2. Configure the “Starting computer” number for all the UltraConsole switches, starting with Unit #2 by:
(Unit #1 default = 1)
a. Connect a KVM station to Unit #2’s KVM connector using the appropriate KVM adapter cable.
b. Apply power to the KVM monitor and to UltraConsole #2.
c. When the internal diagnostic completes, press and release the left control [Ctrl] key, then the F12 key to
display the “Main menu”.
d. Select “System” and press [Enter].
e. Next, select “Starting computer number” and press [Enter]. An input box will display for a new starting
computer number. Enter the correct “Starting computer” number for this Unit (See page 15) and press
[Enter].
f. Press the “Esc” key to return to the “Main menu”.
g. Select “Save” and press [Enter]. A “YES/NO” choice box will display. Select “YES” and press [Enter] to save
the changes.
h. Turn the power off on the UltraConsole.
i. Connect the KVM station to the KVM connector on Unit #3.
j. Configure this Units “Starting computer” number and then all other Units in the system. When the “Starting
computer” number has been entered for all Units, proceed to step 3.
3. Connect the KVM station to Unit #1’s KVM connector and apply power to the monitor and Unit #1.
4. Enter the “Maximum computers” number
a. Display the main menu (left control [Ctrl] key, then the F12 key.)
b. Select “System” and press [Enter].
c. Select “Maximum computers” and press [Enter]. An input box will display for a new “Maximum computers
number. Enter the correct “Maximum computers” value as explained on page 15 and press [Enter].
d. Press the “Esc” key to return to the “Main menu”, select “Save” and press [Enter]. A “YES/NO” choice box
will display. Select “YES” and press [Enter] to save the change.
5. The next item is to connect the Units in a “BUS” configuration and verify that communication between the Units is
established. To do this, call up the System status display by pressing and releasing the left control [Ctrl] key,
then the F12 key.
6. Select “Status” from the Main menu and press [Enter]. The system status screen will display showing the
following: (Figure 13)
a. Computers
b. Power (Power on status)
c. POS (Card position)
d. VER (Program version)
e. KVM
f. CPU
g. User
h. Status
The number of system CPU ports that Unit #1 has will be highlighted. If the Unit is a 16-port switch, computers 14,
5–8, 912, and 1316 will be highlighted on the status screen.